The SSP Standing Seam Roof Panel with the patented VersaLok™ sidelap connection. The panel is a true factory foamed-in-place trapezoidal roof panel with a standing seam offering superior weathertightness. With the IPS patented VersaLok™ sidelap, the roof panels snap together before being mechanically seamed. This Tecfoam panel is filled with non CFC polyurethane modified isocyanurate achieving R-values up to 39.5.
   
Dimensions: Nominal 36" coverage; Thickness (T) ­ 2", 21/2", 3", 4" and 5".
Material: Exterior - 24 ga. steel (std). 26 and 22 ga. also available.
Interior - 26 ga. steel (std). 24 and 22 ga. also available.
Finish Options: Exterior - Galvalume PlusŪ
Signature® 200 (silicone polyester)
Signature® 300 (Kynar 500/Hylar 5000)
  Interior - USDA White (standard)
Signature® 200 (silicone polyester)
Texture: The exterior skin is smooth as a standard and available embossed as an option. The interior skin is embossed only.
Length:

The maximum recommended length is 35'-0". Contact IPS for panel length options.

Fasteners: Concealed clip, 14 ga. steel base with an 18 ga. steel tab.

TEST DATA

Test Purpose Procedure Results
Thermal Resistance Determines insulating
properties of the panels
ASTM C 236
Guarded Hot Box
Good R values for an HCFC Foam System
(see published values for panel type and thickness)
Air Leakage Measures air leakage
through the panel joints
ASTM E 283
Chamber Method
The leakage rate for the SSP panel will not exceed 0.01 CFM/SF at 40 psf pressure differential
Water Penetration Measures water leakage
through the panel joints
ASTM E 331
Chamber Method
No water penetration at pressure differential of
50 psf for the SSP panel
Strength Determines the load/span properties of the roof and wall panels ASTM E 72
Chamber Method
Panel load/span and deflection tables
are available
Wind Uplift Determines uplift resistance of roof panels in high winds Underwriters
Laboratories
UL 580
SSP Roof Panels have a Class 90 rating with
a 7'- 0" purlin spacing
Factory Mutual
STD. 4471(1995)
SSP Roof Panels have a Class 1-75 and 1-90
rating with a 5'- 0" purlin spacing
Determines ultimate uplift capacity of roof panels ASTM E 1592 SSP Roof Panels have an ultimate uplift capacity of
100 psf with a 6'- 0" purlin spacing
Surface Burning Determines the surface
burning characteristics of 
the core and panels
Underwriters
Laboratories UL 723
(ASTM E 84)

Core Material (5")
Flame Spread 20*, Smoke Developed 400

Finished Panels
2" to 5" Panel
Flame Spread 15*, Smoke Developed 
250 - 450

Factory Mutual
ASTM E 84
Core Material (5")
Flame Spread 25*, Smoke Developed 180
Room Fire Test Evaluates the burning of 
roof and wall panels in a
room configuration
Factory Mutual
STD. 4880 (1994)
(UBC 26-3)
All wall and roof panels are rated
Class 1 to 30 ft. high, 5 in. max. thickness
Roof Covering Fire
Test
Evaluates the burning of
roof covering from external fire
Underwriters
Laboratories
UL 790
(ASTM E 108)
The SSP Roof Panel is rated Class A
Factory Mutual
STD. 4471 (1995)
(ASTM E 108)
The SSP Roof Panel
is rated Class A

*The numerical flame spread rating is not intended to reflect hazards presented by this or any other material under actual fire conditions.

THERMAL PROPERTIES

ESP WALL PANEL
Product Code
Thickness
"U" Factor
"R" Factor
SSP 200
2"
.067
14.9
SSP 250
2 1/2"
.053
19.0
SSP 300
3"
.043
23.1
SSP 400
4"
.032
31.3
SSP 500
5"
.025
39.5