| Description: |
The SSP Standing Seam Roof
Panel with the patented VersaLok™ sidelap connection. The
panel is a true factory foamed-in-place trapezoidal roof
panel with a standing seam offering superior weathertightness.
With the IPS patented VersaLok™ sidelap, the roof panels
snap together before being mechanically seamed. This Tecfoam
panel is filled with non CFC polyurethane modified isocyanurate
achieving R-values up to 39.5. |
| Dimensions: |
Nominal 36" coverage; Thickness (T)
- 2", 2-1/2", 3", 4" and 5". |
 |
| Material: |
Exterior – 24 ga. steel (std). 26 and 22
ga. also available.
Interior – 26 ga. steel (std). 24 and 22 ga. also available. |
| Finish Options: |
Exterior – Galvalume PlusŪ
Signature® 200 (silicone polyester)
Signature® 300 (Kynar 500/Hylar 5000)
Interior – USDA
White (standard)
Signature® 200 (silicone polyester) |
| Texture: |
The exterior skin is smooth as a standard
and available embossed as an option. The interior skin
is embossed only. |
| Length: |
The maximum recommended length is 35'-0".
Contact IPS for panel length options. |
| Fasteners: |
Concealed clip, 14 ga.
steel base with an 18 ga. steel tab.
|
|
|
| Test |
Purpose |
Procedure |
Results |
| Thermal Resistance |
Determines insulating
properties of the panels |
ASTM C 236
Guarded Hot Box |
Good R values for an HCFC Foam System
(see published values for panel type and thickness) |
| Air Leakage |
Measures air leakage
through the panel joints |
ASTM E 283
Chamber Method |
The leakage rate for the SSP panel will
not exceed 0.01 CFM/SF at 40 psf pressure differential
|
| Water Penetration |
Measures water leakage
through the panel joints |
ASTM E 331
Chamber Method |
No water penetration at pressure differential
of 50 psf for the SSP panel |
| Strength |
Determines the load/span
properties of the roof and wall panels |
ASTM E 72
Chamber Method |
Panel load/span and deflection tables are
available |
| Wind Uplift |
Determines uplift resistance
of roof panels in high winds |
Underwriters
Laboratories
UL 580 |
SSP Roof Panels have a Class 90 rating
with a 7'- 0" purlin spacing |
Factory Mutual
STD. 4471(1995) |
SSP Roof Panels have a Class
1-75 and 1-90 rating with a 5'- 0" purlin spacing
|
Determines ultimate uplift
capacity of roof panels |
ASTM E 1592 |
SSP Roof Panels have an ultimate
uplift capacity of 100 psf with a 6'- 0" purlin spacing
|
| Surface Burning
|
Determines the surface
burning characteristics of
the core and panels |
Underwriters
Laboratories UL 723
(ASTM E 84) |
Core Material (5")
Flame Spread 20*, Smoke Developed 400
Finished Panels
2" to 5" Panel
Flame Spread 15*, Smoke Developed
250 - 450 |
Factory Mutual
ASTM E 84 |
Core Material (5")
Flame Spread 25*, Smoke Developed 180 |
| Room Fire Test |
Evaluates the burning of
roof and wall panels in a
room configuration |
Factory Mutual
STD. 4880 (1994)
(UBC 26-3) |
All wall and roof panels are rated
Class 1 to 30 ft. high, 5 in. max. thickness |
| Roof Covering
Fire Test |
Evaluates the burning of
roof covering from external fire |
Underwriters
Laboratories
UL 790
(ASTM E 108) |
The SSP Roof Panel is rated Class A |
Factory Mutual
STD. 4471 (1995)
(ASTM E 108) |
The SSP Roof Panel
is rated Class A |
|
|
|
|